 Technical specifications

PowerMortar's properties have been tested in a
concrete research laboratory

Ø Excellent adhesion to stone, concrete and steel

Ø PowerMortar does not shrink

Ø PowerMortar has a high compression strength

Ø PowerMortar is resistant to freezing

Ø PowerMortar's temperature coefficient of expansion is the same as that of concrete

Ø PowerMortar is resistant to salt and chemicals

Ø PowerMortar does not contain water-soluble materials

Ø PowerMortar has low water permeability (prevents rusting of steel )

Ø PowerMortar is alkaline (prevents rusting of steel )

Ø PowerMortar is not carbonised

 

 

 

POWERMORTARTM - TECHNICAL SPECIFICATION

PropertyTest criteriaTest resultTest method
Compressive strength1 d (+20 °C)7 d28 d915 - 30 MPa 40 - 60 MPa 50 - 70 MPa60 - 90 MPa SFS 4474
Flexural strength1 d7 d28 d91 d1,0 - 7,4 MPa6,0 - 7,4 MPa6,4 - 7,7 MPa7,0 - 7,4 MPaSFS 5444
Density
2000 - 2300 kg/m3SFS 5442
Freeze-thaw resistance, 100 sequencesCompressive strength reference freeze-thawFlexural strength reference freeze-thawUltrasonic pulse transmission time reference freeze-thaw Freeze-thaw resistance, 300 sequences Specific surface of air voidsSpacing factor Frost-salt resistanceVolume change
63 MPa60 Mpa 6,5 MPa8,4 MPa 39,2 ms39,5 ms No damage 30 mm2/mm3 (>25 mm2/mm3)0,16 mm (£0,26 mm) 1,1 % (<3,3 %)SFS 5447, By32 Thin section analysis Thin section analysis SFS 5449, By 32
Chemical resistance
Good
Resistance to carbonation
Very goodPhenolphtalein test
Consistency (Slump test)
PlasticSFS 5284
Cohesion
Excellent
Adhesion (Bond strength)
Strong SFS 5446
Pumpability
50 meters along the pipe
Initial set
2 - 5 hours at 15 - 20°C (Relative humidity >90%)
Final set
3 - 6 hour at 15 - 20°C (Relative humidity >90%)
Shrinkage, linear
± 0.01 % ????